JB/T 11211
小型制冷系统用电动切换阀
小型制冷系统用电动切换阀
📋 Scope / 适用范围 ai_extracted
This standard specifies the terms and definitions, types, models and service conditions, requirements, test methods, inspection rules, as well as marking, packaging, transportation, and storage of electric switching valves (hereinafter referred to as "electric valves") for small refrigeration systems. This standard applies to electric switching valves for refrigeration systems using refrigerants such as R600a, R134a, or similar thermodynamic properties, with a valve port diameter not exceeding 1.0 mm.
本标准规定了小型制冷系统用电动切换阀(以下简称“电动阀”)的术语和定义、型式、型号和使 用条件、要求、试验方法、检验规则以及标志、包装、运输、贮存。 本标准适用于R600a、R134a 或类似热力性质的制冷剂,其阀门口径不大于1.0 mm 的制冷系统用 电动切换阀。
📝 Foreword / 前言 ai_extracted
This standard was drafted in accordance with the rules given in GB/T 1.1—2009. This standard was proposed by the China Machinery Industry Federation. This standard is under the jurisdiction of the National Technical Committee on Refrigeration and Air-Conditioning Equipment Standardization of China (SAC/TC238). The main drafting units of this standard: Zhejiang Sanhua Refrigeration Group Co., Ltd., Hefei General Machinery Research Institute. Participating drafting units of this standard: Zhuji Hengsen Refrigeration and Heating Equipment Co., Ltd., Zhejiang Wanjin Machinery Co., Ltd. The main drafters of this standard: Chen Yuzhong, Chen Bin, Shi Min, He Yongshui, Jin Juntao. This standard is issued for the first time. Free download from Guobiao 99 www.gb99.cn JB/T 11211—2011
本标准按GB/T 1.1—2009给出的规则起草。 本标准由中国机械工业联合会提出。 本标准由全国冷冻空调设备标准化技术委员会(SAC/TC238)归口。 本标准主要起草单位:浙江三花制冷集团有限公司、合肥通用机械研究院。 本标准参加起草单位:诸暨市恒森冷热器材有限公司、浙江万金机械有限公司。 本标准主要起草人:陈雨忠、陈斌、史敏、何永水、金均涛。 本标准为首次发布。 国标久久 www.gb99.cn 免费下载 JB/T 11211—2011
📚 References & Relations / 引用与关联
📖 Terms & Definitions / 术语和定义 ai_extracted
- 电动切换阀 step valve / step valve
- 一种步进电动机驱动阀,设置有一个进口和一个或多个出口,按预设的程序控制步进电动机的运转, 电动机转子直接驱动滑块,在预设工作位置改变出口管的开闭状态,从而控制制冷剂流向的电动阀。
- A stepping motor-driven valve, equipped with one inlet and one or more outlets, controls the operation of the stepping motor according to a preset program. The motor rotor directly drives a slider to alter the open/close state of outlet tubes at predetermined working positions, thereby regulating the flow direction of refrigerant in an electric valve.
- 流量特性 air flow late / Flow characteristics
- 流过电动阀各出口的流量与输入步进电动机线圈的脉冲数之关系。
- The relationship between the flow rate through each outlet of the electric valve and the number of pulses input to the stepper motor coil.