GB/T 12160-2002
AbolishedCalibration of extensometers used in uniaxial testing
单轴试验用引伸计的标定
📋 Scope / 适用范围 ai_extracted
This standard specifies the static calibration method for extensometers used in uniaxial testing. The term "extensometer" refers to a displacement measuring device and includes the system for indicating or recording such displacement. Note: This standard currently does not provide detailed guidance for the calibration of the following types of extensometers: - Variable gauge length type; - Non-contact type; - Plane strain measurement type. For the calibration of these types of extensometers, special consideration should be given.
本标准规定了单轴试验用引伸计的静态标定方法。 术语“引伸计”的含义是指位移测量装置并包括指示或记录该位移的系统。 注:本标准目前未提供对下列型式引伸计标定的详细指导 一一变标距式卜 一 非接触试样式: — 平面应变测量式 对于这些型式引伸计的标定宜专门考虑
📝 Foreword / 前言 ai_extracted
This standard is identical to ISO 9513:1999 "Calibration of extensometers used in uniaxial testing of metallic materials" (English second edition), including its Technical Corrigendum 1:2000. This standard is an identical translation of ISO 9513:1999. The text structure and technical content are completely identical to the international standard. However, the following minor editorial modifications have been made in accordance with the relevant regulations for standard compilation in China: - To achieve harmonization and consistency with related standards, the leading element of the standard title has been deleted. - "This standard" is used to replace "This International Standard". - The decimal point symbol "." commonly used in Chinese is used to replace the decimal point symbol "," used in English. - The Foreword of the international standard has been deleted. - The "Bibliography" attached to ISO 9513:1999 (its content is inappropriate for inclusion in this standard) and the last sentence of the note in Clause 1 that corresponds to it have been deleted. - Relevant tables and formulas have been modified according to Chinese expression habits. - Table 2, Figure B.1, and Figure B.2 have been corrected according to the Technical Corrigendum of ISO 9513:1999. These modifications are identified by vertical double lines (||) in the margins of the affected tables and figures. This standard replaces GB/T 12160-1990 "Method for calibration and classification of extensometers". Concurrently, the machinery industry standard JB/T 8289-1999 "Method for calibration and classification of extensometers" (this industry standard number was approved by the former Ministry of Machinery Industry after GB/T 12160-1990 was adjusted to an industry standard during the national standard cleanup and rectification process) is abolished. Compared with GB/T 12160-1990, the main changes in this standard are as follows: - A table of contents and a foreword have been added. - The text structure has been adjusted according to ISO 9513:1999, and the technical content has also changed. - The terms, extensometer calibration coefficient, and the calculation of strain indication error and displacement indication relative error (Clauses 2, 6, and 7 of the 1990 edition) have been deleted. - The informative appendix (Appendix A of the 1990 edition) has been deleted. - Symbols and definitions have been added (Clause 2 of this edition). - The original standard classified extensometers based on the maximum permissible strain indication error. This standard, consistent with ISO 9513:1999, classifies them based on the maximum permissible values of gauge length relative error, resolution, and system relative error (Clause 5 of the 1990 edition; Clause 6 of this edition). - Informative appendices have been added (Appendices A and B of this edition). The national standard related to this standard is GB/T 228-2002 "Metallic materials - Tensile testing at ambient temperature", and it is referenced by that standard. Appendices A and B of this standard are informative appendices. This standard was proposed by the China Machinery Industry Federation. This standard is under the jurisdiction of the National Technical Committee for Standardization of Testing Machines. The responsible drafting organization for this standard is Changchun Testing Machine Research Institute. The participating drafting organizations for this standard are the Central Iron and Steel Research Institute and Jinan Testing Machine Group Co., Ltd. The main drafters of this standard are Liang Enchao, Wang Chunhua, and Tao Liying. The previous versions of the standard replaced by this standard are: GB/T 12160-1990 (JB/T 8289-1999) GB/T 12160-2002/ISO 9513:1999 Calibration of extensometers used in uniaxial testing
本标准等同采用ISO 9513:1999《金属材料单轴试验用引伸计的标定} ) (英文第二版),包括其技 术勘误1:2000 本标准等同翻译ISO 9513:1999,在文本结构和技术内容方面与国际标准完全相同,但根据我国编 写标准的有关规定做了如下小的编辑性修改: -一为与相关标准协调统一,删除了标准名称的引导要素; 一一用, ’本标准”代替“本国际标准”; 一 用中文惯用的小数点符号“.”代替英文采用的小数点符号“,”; — 删除了国际标准的前育; — 删除了ISO 9513:1999所附的“参考文献”(该内容放在本标准中不合适)和第1章注中与其相 呼应的最后一句条文; — 按中文表述习惯修改了有关表格和公式; — 按ISO 9513:1999的技术勘误改正了表2、图B. I和图B. 2,这些改动的内容用垂直双线(} } 在所涉及的表和图的页边空白处予以标识。 本标准代替GB/T 12160-1990( (引伸计标定与分级方法》,同时废止机械行业标准JB/T 8289- 1999( (引伸计标定与分级方法) (此行业标准编号是在国家标准清理整顿过程中,曾将GB/T 12160- 1990调整为行业标准后,由原机械工业部批准的行业标准编号) 本标准与GB/T 12160-199。相比主要变化如下: — 增加了目次和前言; — 文本结构根据ISO 9513:1999进行了调整,技术内容也有所变化; — 删除了术语、引伸计标定系数及应变示值误差和位移示值相对误差的计算(1990年版的第2 章、第6章和第?章); 一 删除了资料性附录(199。年版的附录A); 一一增加了符号和定义(本版的第2章); 一原标准按照最大允许应变示值误差来对引伸计进行分级,本标准则与ISO 9513:1999一致按 照标距相对误差、分辨力和系统相对误差的最大允许值进行分级(1990年版的第5章;本版的 第6章); -一增加了资料性附录(本版的附录A和附录B)o 与本标准相关的国家标准是GB/T 228--2002《金属拉伸试验方法》,并被其引用。 本标准的附录A和附录B均为资料性附录。 本标准由中国机械工业联合会提出 本标准由全国试验机标准化技术委员会归口。 本标准负责起草单位:长春试验机研究所。 本标准参加起草单位:钢铁研究总院、济南试金集团有限公司。 本标准主要起草人:架恩超、王春华、陶立英 本标准所代替的历次版本的发布情况为: GB/T 12160- 1990(JB/T 8289-1999) GB/T 12160-2002/ISO 9513:1999 单轴试验用引伸计的标定
📚 References & Relations / 引用与关联
🔗 Related Standards / 同类标准
Content extracted by AI. Not officially verified.